The mc() method went in endless loops as the exit condition of the while loop was inversed (the method continued looping when the energy was within the valid range and only exited when it was outside). The eval_gradients() method computed the gradients with respect to the parameter values and not the parameter factors. All gradients have be multiplied by the scales. Also, the gradients are now set to 0 if the parameters are fixed. Finally, the parameter "Prefactor" was renamed to "Normalization" because the parameter gives the integral flux under the Gaussian, not the prefactor.
-
The coding and design conventions (CDC) document was also updated.
-
GTestSuites The GTestSuites class now derives from GContainer and implements the usual container class methods (at(), size(), isempty(), set(), append(), insert(), remove(), reserve() and extend()). The operator[] now returns pointers to GTestSuite. The name() and timestamp() methods now return const references. GTestSuite The GTestSuite class now derives from GBase. This implies that the clone() method needs to be implemented for derived classes. The test_assert() method now takes a const reference for the boolean argument. The name(), errors(), failures(), and timestamp() methods return const references. The obsolete add_test() method has been removed. The unit tests have been updated to conform to the new interfaces.
-
The Healpix pixelisation is not a World Coordinate System projection, and to make this clear the name has been changed from GWcsHPX to GHealpix. The code has been adapted to this new naming convention.
-
The GModelPar interface has been revisited and the code has been adapted to satisfy the new interface.
-
This reverts commit 813252eb589e317fd139d0cdde4f20bdd7959ef2.